@@ -112,10 +112,10 @@ void pdb_dpm_get_sink_capability(union pd_msg *cap)
|
112
|
112
|
|
113
|
113
|
/* If we have no configuration or want something other than 5 V, add a PDO
|
114
|
114
|
* for vSafe5V */
|
115
|
|
- if (cfg == NULL || cfg->v != 100) {
|
|
115
|
+ if (cfg == NULL || cfg->v != PD_MV2PDV(5000)) {
|
116
|
116
|
/* Minimum current, 5 V, and higher capability. */
|
117
|
117
|
cap->obj[numobj++] = PD_PDO_TYPE_FIXED
|
118
|
|
- | PD_PDO_SNK_FIXED_VOLTAGE_SET(100)
|
|
118
|
+ | PD_PDO_SNK_FIXED_VOLTAGE_SET(PD_MV2PDV(5000))
|
119
|
119
|
| PD_PDO_SNK_FIXED_CURRENT_SET(DPM_MIN_CURRENT);
|
120
|
120
|
}
|
121
|
121
|
|
|
@@ -125,7 +125,7 @@ void pdb_dpm_get_sink_capability(union pd_msg *cap)
|
125
|
125
|
| PD_PDO_SNK_FIXED_VOLTAGE_SET(cfg->v)
|
126
|
126
|
| PD_PDO_SNK_FIXED_CURRENT_SET(cfg->i);
|
127
|
127
|
/* If we want more than 5 V, set the Higher Capability flag */
|
128
|
|
- if (cfg->v != 100) {
|
|
128
|
+ if (cfg->v != PD_MV2PDV(5000)) {
|
129
|
129
|
cap->obj[0] |= PD_PDO_SNK_FIXED_HIGHER_CAP;
|
130
|
130
|
}
|
131
|
131
|
}
|
|
@@ -164,7 +164,7 @@ bool pdb_dpm_evaluate_typec_current(void)
|
164
|
164
|
|
165
|
165
|
/* If we have no configuration or don't want 5 V, Type-C Current can't
|
166
|
166
|
* possibly satisfy our needs */
|
167
|
|
- if (cfg == NULL || cfg->v != 100) {
|
|
167
|
+ if (cfg == NULL || cfg->v != PD_MV2PDV(5000)) {
|
168
|
168
|
return false;
|
169
|
169
|
}
|
170
|