Python library for working with the PD Buddy Sink Serial Console Configuration Interface
You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
Clara Hobbs 28d9667955 Fix bugs in support for old Pythons 7 vuotta sitten
pdbuddy Fix bugs in support for old Pythons 7 vuotta sitten
test_pdbuddy Added get_source_cap and PDO support 7 vuotta sitten
.gitignore Initial commit 7 vuotta sitten
LICENSE Added a simple PD Buddy Sink configuration library 7 vuotta sitten
README.rst Added get_source_cap and PDO support 7 vuotta sitten
setup.py Bump version number to 0.2.1 7 vuotta sitten

README.rst

pd-buddy-python
===============

Python library for working with the PD Buddy Sink Serial Console
Configuration Interface

Features
--------

- Provides a Pythonic interface to the PD Buddy Sink shell commands
- Configuration is represented as a SinkConfig object
- SinkConfig objects can be manipulated locally and written to the
device with one method call
- Allows control of whether or not the output is enabled
- Provides a Pythonic interface for reading advertised PDOs

Examples
--------

Open the first PD Buddy Sink device and read its configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> import pdbuddy
>>> pdbs = pdbuddy.Sink(list(pdbuddy.Sink.get_devices())[0])
>>> pdbs.get_cfg()
SinkConfig(status=<SinkStatus.VALID: 2>, flags=<SinkFlags.NONE: 0>, v=5000, i=3000)
>>> print(pdbs.get_cfg())
status: valid
flags: (none)
v: 5.00 V
i: 3.00 A

Locally manipulate a SinkConfig object
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> cfg = pdbs.get_cfg()
>>> cfg = cfg._replace(v=20000, i=2250)
>>> cfg = cfg._replace(flags=cfg.flags | pdbuddy.SinkFlags.GIVEBACK)
>>> cfg
SinkConfig(status=<SinkStatus.VALID: 2>, flags=<SinkFlags.GIVEBACK: 1>, v=20000, i=2250)

Write the SinkConfig object to flash
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> pdbs.set_tmpcfg(cfg)
>>> pdbs.write()
>>> pdbs.get_cfg()
SinkConfig(status=<SinkStatus.VALID: 2>, flags=<SinkFlags.GIVEBACK: 1>, v=20000, i=2250)

Requirements
------------

- Python 2.7, >= 3.3
- pySerial >= 3.0
- aenum >= 2.0 (if using Python < 3.6)

Testing
-------

To run the unit tests, run::

$ python setup.py test

This will test the Sink class only if a PD Buddy Sink is plugged in and in
setup mode, so make sure that's the case if you're testing any changes to the
Sink class. Also, make sure the Status LED is blinking quickly when the tests
are run, since that's the only real way to test the ``identify`` command. Be
aware that the Sink's configuration will get clobbered by the tests.