Python library for working with the PD Buddy Sink Serial Console Configuration Interface
Vous ne pouvez pas sélectionner plus de 25 sujets Les noms de sujets doivent commencer par une lettre ou un nombre, peuvent contenir des tirets ('-') et peuvent comporter jusqu'à 35 caractères.
Clara Hobbs 4f82d513a0 Update the test_sink script il y a 6 ans
pdbuddy Update the test_sink script il y a 6 ans
test_pdbuddy Support PPD APDOs il y a 6 ans
.gitignore Initial commit il y a 7 ans
LICENSE Added a simple PD Buddy Sink configuration library il y a 7 ans
README.rst Added get_source_cap and PDO support il y a 7 ans
setup.py Bump version number to 0.4.2 il y a 7 ans

README.rst

pd-buddy-python
===============

Python library for working with the PD Buddy Sink Serial Console
Configuration Interface

Features
--------

- Provides a Pythonic interface to the PD Buddy Sink shell commands
- Configuration is represented as a SinkConfig object
- SinkConfig objects can be manipulated locally and written to the
device with one method call
- Allows control of whether or not the output is enabled
- Provides a Pythonic interface for reading advertised PDOs

Examples
--------

Open the first PD Buddy Sink device and read its configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> import pdbuddy
>>> pdbs = pdbuddy.Sink(list(pdbuddy.Sink.get_devices())[0])
>>> pdbs.get_cfg()
SinkConfig(status=<SinkStatus.VALID: 2>, flags=<SinkFlags.NONE: 0>, v=5000, i=3000)
>>> print(pdbs.get_cfg())
status: valid
flags: (none)
v: 5.00 V
i: 3.00 A

Locally manipulate a SinkConfig object
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> cfg = pdbs.get_cfg()
>>> cfg = cfg._replace(v=20000, i=2250)
>>> cfg = cfg._replace(flags=cfg.flags | pdbuddy.SinkFlags.GIVEBACK)
>>> cfg
SinkConfig(status=<SinkStatus.VALID: 2>, flags=<SinkFlags.GIVEBACK: 1>, v=20000, i=2250)

Write the SinkConfig object to flash
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> pdbs.set_tmpcfg(cfg)
>>> pdbs.write()
>>> pdbs.get_cfg()
SinkConfig(status=<SinkStatus.VALID: 2>, flags=<SinkFlags.GIVEBACK: 1>, v=20000, i=2250)

Requirements
------------

- Python 2.7, >= 3.3
- pySerial >= 3.0
- aenum >= 2.0 (if using Python < 3.6)

Testing
-------

To run the unit tests, run::

$ python setup.py test

This will test the Sink class only if a PD Buddy Sink is plugged in and in
setup mode, so make sure that's the case if you're testing any changes to the
Sink class. Also, make sure the Status LED is blinking quickly when the tests
are run, since that's the only real way to test the ``identify`` command. Be
aware that the Sink's configuration will get clobbered by the tests.