Python library for working with the PD Buddy Sink Serial Console Configuration Interface
您最多选择25个主题 主题必须以字母或数字开头,可以包含连字符 (-),并且长度不得超过35个字符
Clara Hobbs 6d8e976402 Make it obvious when output is unsupported 7 年前
pdbuddy Make it obvious when output is unsupported 7 年前
test_pdbuddy Changed test voltages and currents 7 年前
.gitignore Initial commit 7 年前
LICENSE Added a simple PD Buddy Sink configuration library 7 年前
README.rst Update version number 7 年前
setup.py Bump version number to 0.2.1 7 年前

README.rst

pd-buddy-python
===============

Python library for working with the PD Buddy Sink Serial Console
Configuration Interface

Features
--------

- Provides a Pythonic interface to the PD Buddy Sink shell commands
- Configuration is represented as a SinkConfig object
- SinkConfig objects can be manipulated locally and written to the
device with one method call

Examples
--------

Open the first PD Buddy Sink device and read its configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> import pdbuddy
>>> pdbs = pdbuddy.Sink(list(pdbuddy.Sink.get_devices())[0])
>>> pdbs.get_cfg()
SinkConfig(status=SinkStatus.VALID, flags=SinkFlags.NONE, v=5000, i=3000)
>>> print(pdbs.get_cfg())
status: valid
flags: (none)
v: 5.00 V
i: 3.00 A

Locally manipulate a SinkConfig object
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> cfg = pdbs.get_cfg()
>>> cfg.v = 20000
>>> cfg.i = 2250
>>> cfg.flags |= pdbuddy.SinkFlags.GIVEBACK
>>> cfg
SinkConfig(status=SinkStatus.VALID, flags=SinkFlags.GIVEBACK, v=20000, i=2250)

Write the SinkConfig object to flash
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

::

>>> pdbs.set_tmpcfg(cfg)
>>> pdbs.write()
>>> pdbs.get_cfg()
SinkConfig(status=SinkStatus.VALID, flags=SinkFlags.GIVEBACK, v=20000, i=2250)

Requirements
------------

- Python 2.7, >= 3.3
- pySerial >= 3.0
- aenum >= 2.0 (if using Python < 3.6)

Testing
-------

To run the unit tests, run::

$ python setup.py test

This will test the Sink class only if a PD Buddy Sink is plugged in and in
setup mode, so make sure that's the case if you're testing any changes to the
Sink class. Also, make sure the Status LED is blinking quickly when the tests
are run, since that's the only real way to test the ``identify`` command. Be
aware that the Sink's configuration will get clobbered by the tests.